Four-peptide GHK scaffold in experimental spinal cord injury in minipigs
Animal research · 2026
- What was studied
- Minipig spinal cord transection pilot with two illustrated surgical techniques. The supplement gives no number of implanted animals per technique. Separate PC-12 and SH-SY5Y cell cultures and scaffold mechanics experiments.
- Main finding
- At 24 hours after minipig spinal cord transection and scaffold implantation, the supplement shows host-cell infiltration. Figure S10 documents migration along the scaffold channel with surgical technique 2.
Reported findings and study design
Researchers built a porous, multichannel oligo(polyethylene glycol fumarate) cryogel with β-cyclodextrin. Adamantane groups anchor the linked derivatives Ada-Ahx-GGSIKVAV, Ada-Ahx-GGGHK, Ada-Ahx-GGRGD and Ada-Ahx-GGLRE (Figure S1). The teams used histology and MAP-2 immunofluorescence to examine the implant and spinal cord interface.
Dose, route and schedule
Both surgical techniques were assessed 24 hours after implantation. In separate PC-12 scaffold assays, Figure S3C labels IKVAV and RGD conditions at 1 mM and 2 mM. Actual loading of GHK or the other motifs in the minipig implant was not quantified in the reviewed sources.
Protocol source ↗ · Publisher abstract and Wiley Supporting Information, Figures S1–S10. Main article methods and results were unavailable for review.
| Measure | Result | Comparison, timing and statistics |
|---|---|---|
| Minipig histology with surgical technique 2 | Figure S10 shows sections at the rostral and caudal spinal cord ends and the central channel edge. The authors describe host cells migrating along the channel. | Representative micrographs, including MAP-2 immunofluorescence and DAPI nuclear staining. · 24 hours after implantation |
| Minipig histology with surgical technique 1 | Figure S9 shows scaffold contact with the rostral spinal cord stump, a caudal section detached from spinal cord tissue, and MAP-2 staining at the interface. | Representative micrographs. The two technique figures do not supply a comparative cell count. · 24 hours after implantation |
| PC-12 adherence on individual peptide scaffolds | About 66% adhered with IKVAV or RGD, 56% with GHK and 55% on peptide-free scaffold. | Approximate means from Figure S3A. IKVAV and RGD carry significance markers, while GHK carries none. · 4 hours |
| SH-SY5Y adherence and neural-cell morphology | No significance markers appear for SH-SY5Y adherence in Figure S3B. Figures S4–S5 show representative PC-12 and SH-SY5Y morphology across peptide-free, individual and combined conditions. | |
| PC-12 viability assay with IKVAV or RGD | At 72 hours, the MTS assay signal was about 0.41 with 2 mM IKVAV and 0.38 with 2 mM RGD, versus 0.30 for peptide-free scaffold. | Approximate absorbance at 490 nm from Figure S3C. The 1 mM IKVAV and RGD bars are about 0.32 and 0.31. · n=3, mean ± SD. The figure marks a significant comparison at 2 mM IKVAV (p<0.05). |
| Fluorescent GHK derivative signal during storage | About 3,800 arbitrary units initially and 3,000 at day 28, roughly 80% of the initial signal. | Figure S2A, β-cyclodextrin-containing scaffold stored in water. Fluorescence is a proxy for signal retention, and an absolute mass of retained peptide was not measured in this panel. |
| Channel diameter and scaffold compression | At 2.0 mm channel diameter, compressive Young’s modulus was about 500 kPa versus 610 kPa with no channels. Stress at 200 µm deformation was about 11.8 versus 14.5 kPa. | Approximate means from Figure S8B–C. The shape-recovery panel tested 600–1,800 µm channels under 1 N in 10 mm-diameter gels. · n=3 per condition, mean ± SD. Both 2.0 mm comparisons are marked p<0.001 versus no channels. |
| Independent spinal cord mechanics specimens | Two freshly tested samples and one frozen sample from one young minipig in a separate experiment. | Figure S7C. These are explant specimens, separate from the implanted-animal groups. |
The animal follow-up verified in the supplement is 24 hours. Laboratory sample counts, aqueous storage and scaffold loading conditions apply to the individual bench experiments.
Source for these results ↗ · Reviewed 2026-11-16
Study limitations and source details
Study limitations
- The minipig figures show representative tissue sections at 24 hours. Animal group sizes, per-implant peptide loading, between-technique effect sizes and longer follow-up are unavailable in the reviewed sources.
- The 1 and 2 mM concentrations apply to separate PC-12 scaffold assays of IKVAV and RGD. The 28-day fluorescence series measured a labeled GHK derivative stored in water.
- The study reports early tissue integration. Walking, functional reconnection and long-term axon regeneration remain unverified. The animal images do not isolate GHK’s contribution.
Source details
Publisher abstract and original Wiley supporting document
Publisher abstract and Wiley Supporting Information, Figures S1–S10. Main article methods and results were unavailable for review.
Sources checked
Citation
Published
M. Zoughaib, I. A. Lavrov, K. Dayob, A. Yergeshov, V. V. Andrianov, N. V. Vikherev, M. Kamalov, L. M. Amirova, A. V. Nemtarev, T. I. Abdullin. Four-peptide GHK scaffold in experimental spinal cord injury in minipigs Macromolecular Bioscience. 2026;26(10):e70275. PMID 42908029.
Study source ↗ · DOI 10.1002/mabi.70275 · Bibliography entry · Link to this summary